Relief Panels Are Not Flat Cladding

Standard interior cladding specifications — written for flat sheet materials like plasterboard, HPL, or stone veneer — don’t translate directly to three-dimensional relief panels. Relief panels have variable thickness profiles and weight distributions that change across the panel face. A specification that doesn’t account for this will create problems at installation that are expensive to resolve on site.

The good news: relief panel specification follows the same logic as any material specification. It just requires attention to a few additional parameters that flat cladding doesn’t have.

The Specification Checklist

A complete relief panel specification should address the following parameters. Missing any of these creates ambiguity that the contractor will either price conservatively or resolve incorrectly.

  1. Material. State the material family (e.g. polymer modified composite gypsum). Don’t assume — write it explicitly.
  2. Panel dimensions and tolerances. Specify maximum panel size, nominal thickness, and the allowable dimensional tolerance. For relief panels, tolerance should be stated at both the thinnest and thickest points of the relief profile.
  3. Relief depth and geometry. Define the maximum relief depth (distance from the back plane to the highest point) and whether the geometry is from a supplied 3D file or from the manufacturer’s catalogue. If from a 3D file, state the file format (STEP, OBJ, STL) and the minimum feature radius.
  4. Surface finish. Panels come paint-ready; specify the colour reference (RAL, NCS, or custom match) and the sheen of the paint applied on site.
  5. Fixing method and substrate. State the substrate type (metal stud + plasterboard, masonry, concrete) and the required fixing method. Include maximum allowable deflection of the substrate under panel load.
  6. Joint treatment. Define the joint width between panels, whether joints are expressed (shadow gap) or filled (seamless), and the acceptable joint tolerance.
  7. Pattern continuity. For designs that tile across multiple panels, state whether pattern registration is required and the allowable pattern offset at joints.
  8. Documentation deliverables. List what the manufacturer must provide. Studio Luminant supplies a technical data sheet and an installation drawing for every project.

Fixing Methods

Studio Designs are fixed with a polymer adhesive. On the heavier designs the bottom course also sits on a fixed ledger, each course stands on the one below, and the wall surface is checked before fixing. On metal stud and plasterboard walls, a rail system installed by the contractor carries the load into the studs. Fixing for Hemiola, an open screen block, is set per project. The installation drawing sets the details for each project.

Fixing methods compared
Method Studio Designs Removable?
Polymer adhesive Andante, Ricercar, Fioritura, Mezzavoce, Glissando, Rondeau No, removal is destructive
Polymer adhesive + bottom ledger Antiphon, Melisma, Hocket, Accelerando, Gruppetto, Fugato No, removal is destructive
Rail system (installed by the contractor, per the installation drawing) Any design on a metal stud and plasterboard wall Set in the installation drawing
Hospitality Note

Adhesive-fixed panels do not come off intact, so if your client is a hotel operator, raise the next refresh when the layout is drawn.

Substrate Considerations

The most common mistake in relief panel installation is underestimating the substrate requirements. A standard metal stud + 12.5 mm plasterboard partition is designed for loads of approximately 20–25 kg/m². A standard PMAG panel at 25 mm weighs 35–40 kg/m², and a deep-relief panel at 40 mm 56–64 kg/m² — both exceed the substrate’s capacity.

The solution is not to specify thicker plasterboard (a common but ineffective response), but to ensure the fixing system transfers load directly into the metal studs. Rail-based fixing systems span between studs and distribute the panel weight as point loads on the stud flanges, bypassing the plasterboard entirely. This is structurally sound and eliminates the risk of plasterboard delamination over time.

Where PMAG Is Used

Lumina PMAG™

Weight @ 25mm
35–40 kg/m²
Best for
Interior — hotels, lobbies, column wraps, counter fronts, accent surfaces

Every interior application — hotel corridors, high-rise lobbies, feature walls, column wraps, counter fronts and accent surfaces — is specified in PMAG. The panels are made for interiors; exterior and continuously wet areas are outside their scope.